Dosimetric evaluation of different cylinder diameters in three-dimensional vaginal brachytherapy for early-stage endometrial cancer

· 2024-11-25

To evaluate the dosimetric, radiobiological, and toxicity differences between different cylinder diameters (d) in high-dose-rate three-dimensional computed-tomography-guided vaginal brachytherapy (VBT) for early-stage endometrial cancer (EC). From January 2019 to January 2024, postoperative EC patients treated with exclusive VBT using cylinders were classified by the cylinder diameter (d ≤ 2.6 cm: small-size; d ≥ 3.0 cm: large-size) and matched according to 1:2 propensity score matching. Vaginal clinical target volume (CTV) was a 3-mm expansion around the cylinder surface. Dosimetric parameters in equivalent dose in 2 Gy (EQD2) (α/β = 3 Gy) and equivalent uniform dose (EUD) of vaginal_CTV and organs at risk (OARs) were evaluated. Urinary, gastrointestinal, and vaginal toxicities were assessed using CTCAE v5.0. After matching, 132 patients (small-size: 44; large-size: 88) were analyzed. For vaginal_CTV, the small-size group had higher doses to 2%, 5%, 0.1 cc, 1 cc, and 2 cc of the volume (D Cylinders with smaller diameters produced more nonuniform dose distributions in the target and delivered lower doses to bladder and rectum than large-size cylinders. However, the dosimetric differences did not translate into significant differences of radiobiological parameters or outcomes.
Funding

Special Fund of National Clinical Key Specialty Construction Program of China

2021

Key Specialty program of Natural Science Foundation of Beijing Municipality

Z20008

Hospital key project

BYSYZD202011

Innovation and Translation project of Haidian District

HDCXZHKC2021215