Factors associated with bilateral sentinel lymph node mapping failure using indocyanine green in patients with apparent early-stage cervical cancer: An Italian retrospective multi-center study

Nicolò Bizzarri & Fabio Landoni et al. · 2025-03-20

The primary aim of this study was to assess the factors associated with bilateral mapping failure in patients with apparent early-stage cervical cancer undergoing sentinel lymph node (SLN) biopsy using indocyanine green (ICG). Secondary aims were sensitivity, negative predictive value and lymph node recurrence. Retrospective multi-center study. Patients with cervical cancer apparent FIGO stage IA1 to IIA2, treated with primary surgery between 04/2015 and 12/2023 and undergoing SLN mapping attempt with ICG injection, were included. Appropriate statistical analysis was performed to assess study endpoints. Timeframe was divided in first period 04/2015-12/2019 and second period 01/2020-12/2023. 618 patients were included. Bilateral SLN mapping was achieved in 531 (85.9 %) women (36 of them, 5.8 %, underwent cervical re-injection of ICG). SLN unilateral mapping and mapping failure was observed in 71 (11.5 %) and 16 (2.6 %), respectively. The sensitivity, negative predictive value and accuracy were 85.9 %, 98.1 % and 98.3 %, respectively. False negative rate was 4/68 (5.9 %) in patients with unilateral mapping versus 6/316 (1.9 %) in those with bilateral mapping (p = 0.061). BMI>30 (p = 0.001) and pathologic tumor diameter >20 mm (p = 0.023) were the only factors independently associated with bilateral SLN mapping failure. ICG re-injection increased the rate of bilateral SLN detection from 81.3 % to 85.9 %. The rate of bilateral detection was 82.8 % versus 88.3 % in the first versus second study period, respectively (p = 0.061). 3-year DFS and OS in all patients were 89.7 % and 98.2 %, respectively. Seven patients (1.2 %) had lymph node recurrence in the group of any SLN mapping versus 1 (6.3 %) in no mapping group (p = 0.190). High BMI and larger tumors were associated with bilateral SLN mapping failure using ICG. The ICG cervical re-injection increased the rate of bilateral mapping. No lymph node recurrence difference was found in patients undergoing SLN mapping versus patients with mapping failure.