Investigator

Sergi Vidal-Sicart

Consultor Sénior · Hospital Clinic of Barcelona, Medicina Nuclear

SVSergi Vidal-Sicart
Papers(5)
Paraaortic sentinel l…Sentinel lymph node b…Sentinel lymph node d…Sentinel lymph node m…Steerable DROP-IN rad…
Collaborators(10)
Aureli TornéBerta Díaz-FeijooTiermes Marina MartinNúria CarrerasNuria AgustiAdela SacoPere FustéAriel GlickmanJaume OrdiJaume Pahisa
Institutions(4)
Hospital Clnic De Bar…Fundació de Recerca C…The University of Tex…Institut d'Investigac…

Papers

Paraaortic sentinel lymph node detection in intermediate and high-risk endometrial cancer by transvaginal ultrasound-guided myometrial injection of radiotracer (TUMIR)

We aimed to evaluate the accuracy of sentinel lymph node (SLN) mapping with transvaginal ultrasound-guided myometrial injection of radiotracer (TUMIR) to detect lymph node (LN) metastases, in patients with intermediate and high-risk endometrial cancer (EC), focusing on its performance to detect paraaortic involvement. Prospective study including women with preoperative intermediate or high-risk EC, according to ESMO-ESGO-ESTRO consensus, who underwent SLN mapping using the TUMIR approach. SLNs were preoperatively localized by planar and single photon emission computed tomography/computed tomography images, and intraoperatively by gamma-probe. Immediately after SLN excision, all women underwent systematic pelvic and paraaortic lymphadenectomy by laparoscopy. The study included 102 patients. The intraoperative SLN detection rate was 79.4% (81/102). Pelvic and paraaortic drainage was observed in 92.6% (75/81) and 45.7% (37/81) women, respectively, being exclusively paraaortic in 7.4% (6/81). After systematic lymphadenectomy, LN metastases were identified in 19.6% (20/102) patients, with 45.0% (9/20) showing paraaortic involvement, which was exclusive in 15.0% (3/20). The overall sensitivity and negative predictive value (NPV) of SLNs by the TUMIR approach to detect lymphatic involvement were 87.5% and 97.0%, respectively; and 83.3% and 96.9%, for paraaortic metastases. After applying the MSKCC SLN mapping algorithm, the sensitivity and NPV were 93.8% and 98.5%, respectively. The TUMIR method provides valuable information of endometrial drainage in patients at higher risk of paraaortic LN involvement. The TUMIR approach showed a detection rate of paraaortic SLNs greater than 45% and a high sensitivity and NPV for paraaortic metastases in women with intermediate and high-risk EC.

Sentinel lymph node biopsy versus pelvic lymphadenectomy for early-stage cervical cancer: a retrospective institutional review

Abstract Objective To evaluate the oncologic and survival outcomes in patients diagnosed with early-stage cervical cancer who underwent both sentinel lymph node (SLN) and pelvic lymphadenectomy (PLD) compared with those who underwent SLN alone at primary surgery. Methods From 2001 to 2022, women who underwent SLN biopsy for nodal staging were recruited. The group of women who underwent SLN biopsy and PLD (SLN + PLD group) was compared with the group who underwent SLN mapping alone (SLN group). Results 210 patients were evaluated (98 and 112 in each group). The overall SLN detection rate was 97.6%. Lymph node involvement was detected in 23 patients (11%), and the rate of positive SLN increased from 6.2 to 11% after final pathological examination. At a median follow-up of 80 months, the recurrence and mortality rates were 6.2 and 2.4%, respectively. The 3-year progression-free survival (PFS) rate was 93.7 and 97.2%, and the overall survival (OS) rate was 98.9 and 99.0% in the SLN + PLD and SLN group, respectively. There were no significant differences in the Kaplan–Meier PFS (p = 0.471; HR 0.66; 95% CI 0.22–2.04) and OS (p = 0.228; HR 0.28; 95% CI 0.03–2.53) curves between the groups. Conclusion Pending further confirmation from prospective trials, SLN biopsy appears to be an effective method of nodal assessment in early-stage cervical cancer. This technique does not appear to increase the risk of recurrence compared with complete PLD in selected patients and may offer a viable, less invasive alternative for accurate nodal staging.

Sentinel lymph node detection in early-stage ovarian cancer: a systematic review and meta-analysis

A systematic pelvic and para-aortic lymphadenectomy remains the surgical standard management of early-stage epithelial ovarian cancer. Sentinel lymph node mapping is being investigated as an alternative procedure; however, data reporting sentinel lymph node performance are heterogeneous and limited. This study aimed to evaluate the detection rate and diagnostic accuracy of sentinel lymph node mapping in patients with early-stage ovarian cancer. A systematic search was conducted in Medline (through PubMed), Embase, Scopus, and the Cochrane Library. We included patients with clinical stage I-II ovarian cancer undergoing a sentinel lymph node biopsy and a pelvic and para-aortic lymphadenectomy as a reference standard. We conducted a meta-analysis for the detection rates and measures of diagnostic accuracy and assessed the risk of bias using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO) with identifying number CRD42022351497. After duplicate removal, we identified 540 studies, 18 were assessed for eligibility, and nine studies including 113 patients were analyzed. The pooled detection rates were 93.3% per patient (95% CI 77.8% to 100%; I Sentinel lymph node biopsy in early-stage ovarian cancer showed a high detection rate and negative predictive value. The utero-ovarian and infundibulo-pelvic injection using the indocyanine green and technetium-99 combination could increase sentinel lymph node detection rates. However, given the limited quality of evidence and the small number of reports, results from ongoing trials are awaited before its implementation in routine clinical practice.

Steerable DROP-IN radioguidance during minimal-invasive non-robotic cervical and endometrial sentinel lymph node surgery

Abstract Purpose The recently introduced tethered DROP-IN gamma probe has revolutionized the way robotic radioguided surgery is performed, fully exploiting the nature of steerable robotic instruments. Given this success, the current first-in-human study investigates if the DROP-IN can also provide benefit in combination with steerable non-robotic instruments during conventional laparoscopic surgery, showing equivalence or even benefit over a traditional rigid gamma probe. Methods The evaluation was performed in ten patients during laparoscopic cervical (n = 4) and endometrial (n = 6) cancer sentinel lymph node (SLN) procedures. Surgical guidance was provided using the hybrid, or bi-modal, SLN tracer ICG-99mTc-nanocolloid. SLN detection was compared between the traditional rigid laparoscopic gamma probe, the combination of a DROP-IN gamma probe and a steerable laparoscopic instrument (LaproFlex), and fluorescence imaging. Results The gynecologists experienced an enlarged freedom of movement when using the DROP-IN + LaproFlex combination compared to the rigid laparoscopic probe, making it possible to better isolate the SLN signal from background signals. This did not translate into a change in the SLN find rate yet. In both cervical and endometrial cancer combined, the rigid probe and DROP-IN + LaproFlex combination provided an equivalent detection rate of 96%, while fluorescence provided 85%. Conclusion We have successfully demonstrated the in-human use of steerable DROP-IN radioguidance during laparoscopic cervical and endometrial cancer SLN procedures, expanding the utility beyond robotic procedures. Indicating an improved surgical experience, these findings encourage further investigation and consideration on a path towards routine clinical practice and improved patient outcome. Trial registration HCB/2021/0777 and NCT04492995; https://clinicaltrials.gov/study/NCT04492995

Clinical Trials (1)

NCT07508306Faculty of Medicine of Tunis

Patent Blue SLN in Early Ovarian Cancer Prospective Study (FIGO I-II) Evaluating Patent Blue SLN Mapping. Injection Into IP/UO Ligaments in Situ. Goals: Assess Feasibility and Accuracy vs Standard Lymphadenectomy to Minimize Surgical Morbidity

the standard of care in case of early ovarian cancer (stage I or II) is a complete surgery. This surgery includes : hysterectomy (remove of the uterus), bilateral salpingo-oophorectomy (remove of the adnexa), omentectomy (remove of the epiploon), bilateral pelvic lymphadenectomy (remove of pelvic lymph nodes) and para-aortic lymphadenectomy (remove of para-aortic lymph nodes). This procedure is diagnostic, curative and prognostic surgery. In fact, it allows us provider care giver to stratify the stage of the cancer, hence we give the appropriate adjuvant therapy. However, this surgery, especially the extended lymphadenectomy, is associated with some risks: lymphocele, vessel injury, blood loss, morbidity, long recovery period ... In order to reduce these risks, we propose a sentinel lymph node biopsy. This intervention allows us to detect first lymph node relay whether pelvic or para-aortic. In our study, we chose the patent blue dye as a tracer. This tracer is widely used in oncologic surgery (for example in breast cancer) and approved but not in ovarian cancer yet. During surgery for early stage ovarian cancer, we will inject the patent blue dye on both side of the ovarian tumor. Then, we will check for first colorful lymph node, in both pelvic and para-aortic regions. We will send these dissected lymph node to pathology for analysis. Finally, we will continue the procedure as the standard of care. Our objective is to compare the results between the sentinel lymph node and the complete lymphadenectomy and to study the technique of sentinel lymph node biopsy using the blue patent dye as tracer.

228Works
5Papers
24Collaborators
1Trials

Positions

2014–

Consultor Sénior

Hospital Clinic of Barcelona · Medicina Nuclear

1999–

Especialista

Consorci Parc de Salut MAR de Barcelona · Medicina Nuclear

Education

2001

Doctor

Universitat de Barcelona · Medicina

Country

ES

Links & IDs
0000-0002-6303-3606

Scopus: 7004129488