Investigator

Rossana Moroni

Statistician PhD · Independent Researcher

RMRossana Moroni
Papers(2)
Comparison of Differe…Diagnostic performanc…
Collaborators(8)
Stefano RestainoVincenzo TarantinoAnna FagottiF. MasciliniG. BolominiGiovanni ScambiaNicolò BizzarriRosanna Esposito
Institutions(3)
Agostino Gemelli Univ…University Of PisaMayo Clinic

Papers

Comparison of Different Near-Infrared Technologies to Detect Sentinel Lymph Node in Uterine Cancer: A Prospective Comparative Cohort Study

Objectives: Sentinel lymph node biopsy is considered a crucial step in endometrial cancer staging. Cervical injection has become the most favored technique and indocyanine green has been demonstrated to be more accurate than other tracers. Different near-infrared camera systems are currently being used to detect indocyanine green in sentinel lymph nodes and have been compared in different patients. The present study aimed to determine the number and site of sentinel lymph nodes detected in the same patients with two different near-infrared technologies. Methods: This is a prospective, single-center, observational, non-sponsored study. Patients with presumed uterine-confined endometrial cancer were prospectively enrolled. After cervical injection, two different near-infrared cameras were used to detect sentinel lymph nodes at the same time: Olympus, Tokyo, Japan—considered the standard (SNIR); and Medtronic, Minneapolis, MN, USA with VISION SENSE® which is a new laser near-infrared (LNIR) fluorescence laparoscope. The two cameras were alternatively switched on to detect sentinel lymph nodes in the same patients. Results: Seventy-four consecutive patients were included in the study. Most of the patients were diagnosed with endometrioid histology (62, 83.8%), FIGO stage IA (48, 64.9%), grade 2 (43, 58.1%), and underwent surgery with laparoscopic approach (70, 94.0%). The bilateral detection rate was 56/74 (75.7%) with SNIR and 63/74 (85.1%) with LNIR (p = 0.214). The total number of sentinel lymph nodes identified in the left hemipelvis was 65 and 70 with SNIR and LNIR, respectively; while in the right hemipelvis, there were 74 and 76, respectively. The median number of sentinel lymph nodes identified with SNIR and LNIR was 2 (range, 0–4) and 2 (range, 0–4), respectively (p = 0.370). No difference in site of sentinel lymph node detection was evident between the two technologies (p = 0.994). Twelve patients (16.2%) had sentinel lymph node metastasis: in all cases metastatic sentinel lymph nodes were detected both with Olympus and LNIR. Conclusions: No difference in bilateral detection rate and number or site of sentinel lymph node detection was evident comparing two different technologies of near-infrared camera for ICG detection in endometrial cancer patients. No difference in sentinel lymph node metastases identification was detected between the two technologies.

Diagnostic performance of ultrasound in assessing the extension of disease in advanced ovarian cancer

Surgical exploration remains the gold standard for evaluating the extension of disease and predicting resectability. A laparoscopy-based scoring model was developed by Fagotti and colleagues in 2006 and updated in 2015, based on the intraoperative presence or absence of some specific cancer features. The model proved an overall accuracy rate of 77% to 100% and is considered the reference test for assessing resectability in our institution. The primary aim of the study was to analyze the agreement between preoperative ultrasound examination and laparoscopic findings in assessing the extension of intraabdominal disease using 6 parameters described by Fagotti's score. This was a prospective single-center observational study. Between January 2019 and June 2020, consecutive patients with clinical or radiological suspicion of ovarian or peritoneal cancer were assessed with preoperative ultrasound examination and assigned a score based on the 6 Fagotti score parameters (great omentum, liver surface, lesser omentum/stomach/spleen, parietal peritoneum, diaphragms, bowel disease). Presence of mesenteral retraction of the small bowel and miliary carcinomatosis on the serosa were also evaluated. Each parameter was correlated with laparoscopic findings. Concordance was calculated between ultrasound and laparoscopic parameters using Cohen's kappa. Cohen's kappa ranged from 0.70 to 0.90 for carcinomatosis on the small or large bowel, supracolic omentum, liver surface, and diaphragms. Cohen's kappa test was lower for carcinomatosis on the parietal peritoneum (k=0.63) and on the lesser omentum or lesser curvature of the stomach or spleen (k=0.54). The agreement between ultrasound and surgical predictive index value (score) was k=0.74. For the evaluation of mesenteral retraction and miliary carcinomatosis, the agreement was low (k=0.57 and k=0.36, respectively). The results of ultrasound and laparoscopy in the assessment of intraabdominal tumor spread were in substantial agreement for almost all the parameters. Ultrasound examination can play a useful role in the preoperative management of patients with ovarian cancer when used in dedicated referral centers.

52Works
2Papers
8Collaborators

Positions

2023–

Statistician PhD

Independent Researcher

2018–

Statistician

Fondazione Policlinico Universitario A. Gemelli IRCCS · Direzione scientifica

Country

IT

Links & IDs
0000-0002-3477-6136

Scopus: 24822124900