Investigator

Lucia Manganaro

Policlinico Umberto I

LMLucia Manganaro
Papers(2)
The performance of th…Staging, recurrence a…
Institutions(1)
Policlinico Umberto I

Papers

The performance of the node reporting and data system 1.0 (Node-RADS) and DWI–MRI in staging patients with cervical carcinoma according to the new FIGO classification (2018)

Abstract Purpose To evaluate the diagnostic accuracy of the Node-RADS score and the utility of apparent diffusion coefficient (ADC) values in predicting metastatic lymph nodes (LNs) involvement in cervical cancer (CC) patients using magnetic resonance imaging (MRI). The applicability of the Node RADS score across three readers with different years of experience in pelvic imaging was also assessed. Material and methods Among 140 patients, 68 underwent staging MRI, neoadjuvant chemotherapy and radical surgery, forming the study cohort. Node-RADS scores of the main pelvic stations were retrospectively determined to assess LN metastatic likelihood and compared with the histological findings. Mean ADC, relative ADC (rADC), and correct ADC (cADC) values of LNs classified as Node-RADS ≥ 3 were measured and compared with histological reports, considered as gold standard. Results Sensitivity, specificity, positive and negative predictive values (PPVs and NPVs), and accuracy were calculated for different Node-RADS thresholds. Node RADS ≥ 3 showed a sensitivity of 92.8% and specificity of 72.5%. Node RADS ≥ 4 yielded a sensitivity of 71.4% and specificity of 100%, while Node RADS 5 yielded 42.9% and 100%, respectively. The diagnostic performance of mean ADC, cADC and rADC values from 78 LNs with Node-RADS score ≥ 3 was assessed, with ADC demonstrating the highest area under the curve (AUC 0.820), compared to cADC and rADC values. Conclusion The Node-RADS score provides a standardized LNs assessment, enhancing diagnostic accuracy in CC patients. Its ease of use and high inter-observer concordance support its clinical utility. ADC measurement of LNs shows promise as an additional tool for optimizing patient diagnostic evaluation.

Staging, recurrence and follow-up of uterine cervical cancer using MRI: Updated Guidelines of the European Society of Urogenital Radiology after revised FIGO staging 2018

The recommendations cover indications for MRI examination including acquisition planes, patient preparation, imaging protocol including multi-parametric approaches such as diffusion-weighted imaging (DWI-MR),  dynamic contrast-enhanced imaging (DCE-MR) and standardised reporting. The document also underscores the value of whole-body 18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) and highlights potential future methods. In 2019, the ESUR female pelvic imaging working group reviewed the revised 2018 FIGO staging system, the up-to-date clinical management guidelines, and the recent imaging literature. The RAND-UCLA Appropriateness Method (RAM) was followed to develop the current ESUR consensus guidelines following methodological steps: literature research, questionnaire developments, panel selection, survey, data extraction and analysis. The updated ESUR guidelines are recommendations based on ≥ 80% consensus among experts. If ≥ 80% agreement was not reached, the action was indicated as optional. The present ESUR guidelines focus on the main role of MRI in the initial staging, response monitoring and evaluation of disease recurrence. Whole-body FDG-PET plays an important role in the detection of lymph nodes (LNs) and distant metastases. • T2WI and DWI-MR are now recommended for initial staging, monitoring of response and evaluation of recurrence. • DCE-MR is optional; its primary role remains in the research setting. • T2WI, DWI-MRI and whole-body FDG-PET/CT enable comprehensive assessment of treatment response and recurrence.

2Papers