Investigator

L. Cozzi

Clinical Research Scientist · IRCCS Humanitas Research Hospital, Radiation Oncology

Research Interests

LCL. Cozzi
Papers(2)
Treatment planning co…A novel external beam…
Institutions(1)
Irccs Humanitas Resea…

Papers

Treatment planning comparison of volumetric modulated arc therapy employing a dual-layer stacked multi-leaf collimator and helical tomotherapy for cervix uteri

AbstractPurposeTo ascertain the dosimetric performance of a new delivery system (the Halcyon system, H) equipped with dual-layer stacked multi-leaf collimator (MLC) for risk-adapted targets in cervix uteri cancer patients compared to another ring-based system in clinical operation (Helical Tomotherapy, HT).MethodsTwenty patients were retrospectively included in a treatment planning study (10 with positive lymph nodes and 10 without). The dose prescription (45Gy to the primary tumour volume and a simultaneously integrated boost up to 55Gy for the positive patients) and the clinical planning objectives were defined consistently as recommended by an ongoing multicentric clinical trial. Halcyon plans were optimised for the volumetric modulated arc therapy. The plan comparison was performed employing the quantitative analysis of the dose-volume histograms.ResultsThe coverage of the primary and nodal target volumes was comparable for both techniques and both subsets of patients. The primary planning target volume (PTV) receiving at least 95% of the prescription isodose ranged from 97.2 ± 1.1% (node-negative) to 99.1 ± 1.2% (node-positive) for H and from 96.5 ± 1.9% (node-negative) to 98.3 ± 0.9% (node-positive) for HT. The uncertainty is expressed at one standard deviation from the cohort of patient per each group. For the nodal clinical target volumes, the dose received by 98% of the planning target volume ranged 55.5 ± 0.1 to 56.0 ± 0.8Gy for H and HT, respectively. The only significant and potentially relevant differences were observed for the bowels. In this case, V40Gyresulted 226.3 ± 35.9 and 186.9 ± 115.9 cm3for the node-positive and node-negative patients respectively for Halcyon. The corresponding findings for HT were: 258.9 ± 60.5 and 224.9 ± 102.2 cm3. On the contrary, V15Gyresulted 1279.7 ± 296.5 and 1557.2 ± 359.9 cm3for HT and H respectively for node-positive and 1010.8 ± 320.9 versus 1203.8 ± 332.8 cm3for node-negative.ConclusionThis retrospective treatment planning study, based on the dose constraints derived from the Embrace II study protocol, suggested the essential equivalence between Halcyon based and Helical Tomotherapy based plans for the intensity-modulated rotational treatment of cervix uteri cancer. Different levels of sparing were observed for the bowels with H better protecting in the high-dose region and HT in the mid-low dose regions. The clinical impact of these differences should be further addressed.

A novel external beam radiotherapy method for cervical cancer patients using virtual straight or bending boost areas; an in-silico feasibility study

Abstract Aim To investigate the potential role of a novel spatially fractionated radiation therapy (SFRT) method where heterogeneous dose patterns are created in target areas with virtual rods, straight or curving, of variable position, diameter, separation and alignment personalised to a patient’s anatomy. The images chosen for this study were CT scans acquired for the external beam part of radiotherapy. Methods Ten patients with locally advanced cervical cancer were retrospectively investigated with SFRT. The dose prescription was 30 Gy in 5 fractions to 90% target volume coverage. Peak-and-valley (SFRT_1) and peak-only (SFRT_2) strategies were applied to generate the heterogeneous dose distributions. The planning objectives for the target (CTV) were D90% ≥ 30 Gy, V45Gy ≥ 50–55% and V60Gy ≥ 30%. The planning objectives for the organs at risk (OAR) were: D2cm3 ≤ 23.75 Gy, 17.0 Gy, 19.5 Gy, 17.0 Gy for the bladder, rectum, sigmoid and bowel, respectively. The plan comparison was performed employing the quantitative analysis of the dose-volume histograms. Results The D2cm3 was 22.4 ± 2.0 (22.6 ± 2.1) and 13.9 ± 2.9 (13.2 ± 3.0) for the bladder and the rectum for SFRT_1 (SFRT_2). The results for the sigmoid and the bowel were 2.6 ± 3.1 (2.8 ± 3.0) and 9.1 ± 5.9 (9.7 ± 7.3), respectively. The hotspots in the target volume were V45Gy = 43.1 ± 7.5% (56.6 ± 5.6%) and V60Gy = 15.4 ± 5.6% (26.8 ± 6.6%) for SFRT_1 (SFRT_2). To account for potential uncertainties in the positioning, the dose prescription could be escalated to D90% = 33–35 Gy to the CTV without compromising any constraints to the OARs Conclusion In this dosimetric study, the proposed novel planning technique for boosting the cervix uteri was associated with high-quality plans, respecting constraints for the organs at risk and approaching the level of dose heterogeneity achieved with routine brachytherapy. Based on a sample of 10 patients, the results are promising and might lead to a phase I clinical trial.

502Works
2Papers
PrognosisLiver NeoplasmsHead and Neck NeoplasmsUterine Cervical NeoplasmsCarcinoma, HepatocellularDisease ManagementThymus NeoplasmsBreast Neoplasms

Positions

Clinical Research Scientist

IRCCS Humanitas Research Hospital · Radiation Oncology

2015–

Adjunct Professor

Humanitas University · Faculty of Medicine

Country

IT

Links & IDs
0000-0001-7862-898X

Scopus: 7005647377

Researcher Id: GZL-4895-2022